The Qubino Smart Meter can be used in residential, industrial and utility applications. It measures energy directly in 2-wire networks by means of fast sampling of voltage and current signals. It calculates energy, power and power factor from the measured signals. You can control the module through the Z-Wave network. It also acts as a repeater in order to improve the range and stability of the Z-Wave network. The Smart Meter is designed to be mounted on a DIN rail.
The simplest installation.
There is no simpler installation than DIN rail installation ? and the Qubino Smart Meter is a DIN rail mounted module. Watch the video to learn more.
Incredibly fast support. Free.
We know that when you need information you need it quickly. That is why we offer a live customer service helpline, where you can get instant answers to all your questions. Free. All our support and training is personalized and free of charge.
The most tested and most reliable module.
Qubino modules are “install-and-forget” products. Our products are made to last, so we only select and use top-quality electronic components. Our modules are also the most tested Z-Wave microcontrollers on the market. The Slovenian Institute of Quality and Metrology (SIQ), an independent testing body, tests safety parameters including temperature rise, construction, insulation resistance, power consumption and overload in accordance with the EN 60669-2-1 standard.
Technical specifications
| Main terminals (LI, NI, Lo, No) | |
| Contacts capacity: | 1.5 … 16 (25) mm2 |
| Connection screws: | M5 |
| Max torque: | 3.5 Nm (PZ2) |
| Optional terminals (1,2,4,5) | |
| Contact capacity: | 0.05 … 1 (2.5) mm2 |
| Screws: | M3 |
| Max torque: | 0.6 Nm |
| Measuring input: | |
| Type (connection): | single phase (1b) |
| Reference current (Iref): | 5 A |
| Maximum current (Imax): | 65 A |
| Minimum current (Imin): | 0.25 A |
| Starting current: | 20 mA |
| Voltage (Un): | 230 V (?20%) |
| Power consumption at Un: | < 2 W |
| Nominal frequency (fn): | 50 and 60 Hz |
| Accuracy: | |
| Active energy and power: | |
| Standard EN 62053-21: | class 1 |
| Standard EN 50470-3: | class?B |
| Reactive energy: | |
| Standard EN 62053-23: | class 2 |
| Optical communication: | |
| Type: | IR – used to control BICOM432-40-IR |
| Input (1): | |
| Rated voltage: | 230 V (? 20%) |
| Input resistance: | 450 kOhm |
| Safety: | |
| Indoor Meter: | yes |
| Degree of pollution: | 2 |
| Protection class: | II |
| AC voltage test: | 4 kV |
| Installation Category: | 300 VRMS Cat. III |
| Standard: | EN 50470 |
| Ambient conditions and EMC: | Meets standards for indoor active energy meters. Temperature and climatic conditions to EN 62052-11 |
| Ambient conditions and Safety: | Meets standards for indoor active energy meters. Temperature and climatic conditions to EN 62052-11 |
| Dust/water protection: | IP20 |
| Operating temperature: | -10 … 40?C |
| Storage temperature: | -40 … 70?C |
| Enclosure material: | self-extinguishing |
| UL94 V compliant | yes |
| Indoor meter: | yes |
| Degree of pollution: | 2 |
| AC voltage test: | 4 kV |
| Standard: | EN 50470 |
| Distance: | up to 30 m indoors (depending on building materials) |
| Weight (with packaging): | 150 g (170 g) |
| Frequency range: | 868.4 MHz, Z-Wave |
| Installation | Din rail 35 mm |
| Dimensions (WxHxD): | 36 x 90 x 64 mm |
Supported Z-Wave Frequencies
| ORDERING CODE | FREQUENCY |
| ZMNHTD1 | 868.42 MHz |
| ZMNHTD2 | 921.42 MHz |
| ZMNHTD3 | 908.42 MHz |
| ZMNHTD4 | 869 MHz |
| ZMNHTD5 | 916 MHz |
| ZMNHTD8 | 865.2 MHz |